uCan Health Logo Tell a friend by email tell a friend | 866.880.8226 

Promoting Healthy Living

Follow on Facebook Follow on Twitter Follow on Google+ special tracking
Compare Products Side by Side
Home > Home Care > Mattress, Pillow and Sheet > Alternating Pressure Mattress

MED-AIRE 8" Alternating Pressure Mattress Overlay With Low Air Loss

Item No. Description Price Quant
14028 Complete System $1,099
14028-Cell Cell For 14028 $89
14028-Cell1 Cell W/ Laser Hole For 14028 $89
14028B Carry Bag $109
14028C Cover For 14028 $129
14028M Mattress For 14028 $529
14028P Pump For 14028 $649

For use in the prevention and treatment of decubitis ulcers, the overlay features 4 air cell pillow function increase patient comfort. This alternating pressure mattress Mattress has 20 air bladders, 9 with laser cut low air loss function to increase patient comfort: helps keep the patient cool and speeds recovery.

FEATURES for MED-AIRE 8" Alternating Pressure Mattress Overlay With Low Air Loss


  • LED indicators provide critical performance data and alert caregiver when pressure falls below 10mmHg.Special vibration isolating features insure that the patient rests easily.
  • The Nylon/TPU cover material is heavy weight, water resistant, vapor permeable, has a fiber quilted bottom and is machine washable to provide protection and comfort. The cover attaches to the mattress with snaps.
  • Easy to replace individual bladders.
  • Spring lined air tubes prevents kinks and disruption of air pressure.
  • Quick fill adapter and carry bag standard.
  • The quiet, high volume pump produces 8 LPM of pressure.
  • 8" cells are constructed with Nylon/50% TPU that is firm and heavy weight.
  • CPR valves provide fast (20 second) release of air from the mattress.
  • Low sheer, quilted machine washable cover.
  • 1 year warranty on pump and mattress.

SPECIFICATIONS for MED-AIRE 8" Alternating Pressure Mattress Overlay With Low Air Loss

The Controller

Power: 110V / 60Hz
Air Volume: 8 LPM
Size: 5" W x 3.3" D x 11" H
Cycle Time: 10 min
Pressure Range: 30 - 80 mmHg
Power Cord: 10 feet
 
The Mattress

Size (inflated): 80" L x 36" W x 8" H
Weight Capacity: 300 lbs.

Thera-Turn Millennium Lateral Rotation And Low Air Loss Mattress System

Item No. Description Price Quant
SYS-MIL-TTL Standard 36" Wide $5,599
SYS-MIL-TMP Bariatric 48" Wide $8,299
24-SM-MILLTT-R Replacement Pump For 36" Standard Model SYS-MIL-TTL $3,999
54A34LAL-TM Mattress Cover For Thera-Turn Standard Mattress $369

The Thera Turn Millennium is the ultimate in rotational therapy featuring lateral rotation for pulmonary patients and secondary fro wound healing and prevention. It allows to isolate the patients left and right side on both the angle and time of turn.

FEATURES for Thera-Turn Millennium Lateral Rotation And Low Air Loss Mattress System


  • Incorporating low air loss therapy, state of the art digital and sensor technology, the Thera-Turn Millennium provides superior rotation along with unmatched patient comfort and unparalleled flexibility. 
  • The system features low air loss with patented Microvent technology that sends a controlled gentle airflow directly to the patient's skin.
  • The patented cover is machine washable and breathable, yet provides a barrier to moisture and microbe transmission.
  • Lateral Rotation: automatically turns patients up to 40o to reduce the risk of pulmonary and other serious medical complications associated with immobility. Both angle of turn and turning frequency can be independently programmed on each side.
    • Angle of Turn: caregivers can select form their choice of four pre-programmed turning angles - Off, Gentle, Moderate and Full.
    • Frequency of Turns: desired turning duration can be set from 4 to 90 min.
  • Hold Position: automatic turn cycle can be halted and the patient held in a left, right or center position for nursing intervention.
    • Choice of Positions: patient can be held in either the left, right or center position.
    • Angle of Hold: caregivers can select from their choice of Gentle, Moderate or Maximum angle of hold.
    • Comfort Level: while patient is in the center position, caregivers can adjust the comfort level for optimal patient comfort.
  • Easy Maintenance: the system provides continuous feedback to help you maintain your system in optional condition and provide you with many years of worry-free operation.
  • State of the Art Features: easy touch pad, panel lockout for security, remains inflated during power failure, internal memory, firm mode.
  • Easy to Install on any standard hospital bed. The 8 vertical air cells are individually zippered in place to maintain correct positioning and to simplify replacement. 

SPECIFICATIONS for Thera-Turn Millennium Lateral Rotation And Low Air Loss Mattress System

The Controller

Power: 120V / 60Hz, <1.0A
Weight: 21 lbs.
Size: 14.5" W x 6" D x 12.1" H
Turn Frequency: 4-90 min (left/right)
Turn Frequency: 0-90 min (center)
 
The Mattress

Width (inflated): 36" W (Standard)
Width (inflated): 48" W (Bariatric)
Length x Thickness (Inflated): 80" L x 12" H
Weight: 24 lbs.
Patient Weight Range: 80 - 300 lbs. (Standard)
Patient Weight Range: up to 750 lbs. (Bariatric)
Patient Height Range: 50" - 75"
Share: Social Net FacebookTwitterGoogleGoogle BookmarksLinkedinTumblrBaiduAdd to Favorites / BookmarkDiggRedditTechnerd Communication